Ratry Bag Packaging Machine in addition to give us a very fast, efficient packaging experience, but also because of the failure to give us trouble, in order to facilitate the better use of the bag packaging machine, today we will introduce the bag packaging machine suction cups do not suck the bag of the problem solution
1- Check the bag packaging machine to take the bag of vacuum electronic valve there is no signal output, if not then there may be a problem with the program, the need for professional maintenance.
2- Vacuum valve did not join the positive air pressure, so in the use of the process will lead to the phenomenon of gas break.
3- The vacuum solenoid valve is damaged, you can disassemble the solenoid valve for overhaul, repair and continue to use, if not, you need to replace the corresponding solenoid valve.
4- Check whether there is any foreign matter blocking inside the pipeline, if so, clean up the internal foreign matter and resume normal operation.
5- If the suction drops to half, it is probably because the suction is not enough, you can adjust the suction to recover, if the adjustment of suction is still not working, check whether the air pressure inside the tank is normal, or whether the pipeline is broken.
6- Check whether the suction cup is damaged, if after checking the suction cup does not appear damaged, broken and other issues, but also need to check whether it is because of the quality of the suction cup, the recent replacement of the suction cup is not the same as before, if this is the case on the replacement of the previous suction cup for testing, if the problem is still in the consideration of other situations. In fact, many failures to the bag packaging machine are precursors, usually if you pay attention to regular maintenance, then you can avoid the appearance of many failures.